All Pages8021X HOWTOACP ModemACPI HOWTOADSL Bandwidth Man..ATA RAID HOWTOATM Linux HOWTOAX25 HOWTOAccessibility Dev ..Accessibility HOWTOAdv Bash Scr HOWTOAdv Routing HOWTOAntares RAID sparc..Apache Compile HOWTOApache WebDAV LDAP..Assembly HOWTOAstronomy HOWTOAthlon Powersaving..Authentication Gat..Autodir HOWTOAviation HOWTOAvr Microcontrolle..BRIDGE STP HOWTOBTTVBackspaceDeleteBandwidth Limiting..Bangla HOWTOBash Prompt HOWTOBattery PoweredBelarusian HOWTOBelgian HOWTOBeowulf HOWTOBocaBogoMipsBootdisk HOWTOBridgeC++ dlopenC C++Beautifier HO..C editing with VIM..CDROM HOWTOCDServer HOWTOCable ModemCaudium HOWTOClone HOWTOCompaq Remote Insi..Compaq T1500 HOWTOConexant+Rockwell ..Cryptoloop HOWTODB2 HOWTODHCPDSL HOWTODVD Playback HOWTODebian Binary Pack..Debian JigdoDebian and Windows..Disk Encryption HO..Disk on Chip HOWTODocBook Demystific..DocBook InstallDocBook OpenJade S..Ecology HOWTOEmacspeak HOWTOEncourage Women Li..Encrypted Root Fil..Euro Char SupportEvent HOWTOFedora Multimedia ..Finnish HOWTOFirewall PiercingFlash Memory HOWTOFont HOWTOFramebuffer HOWTOGCC HOWTOGIS GRASSGlibc Install HOWTOHOWTO HOWTOHOWTO INDEXHP HOWTOHandspring VisorHard Disk UpgradeHardware HOWTOHighQuality Apps H..Home Electrical Co..IBM7248 HOWTOIO Perf HOWTOIP AliasIP Masquerade HOWTOIRCImplement Sys Call..Indic Fonts HOWTOInfrared HOWTOIngresII HOWTOInstall StrategiesInstallation HOWTOInstallfest HOWTOIntkeybItalian HOWTOJabber Server Farm..JavaStation HOWTOKerberos Infrastru..Kernel HOWTOKerneldKodak Digitalcam H..LDAP HOWTOLDP Reviewer HOWTOLILO crash rescue ..LVM HOWTOLeased LineLegoLinksys Blue Box R..Linux+Win95Linux+Win9x+Grub H..Linux+Windows HOWTOLinux Complete Bac..Linux Crash HOWTOLinux Gamers HOWTOLinux Modem SharingLinux Promise RAID..Linux i386 Boot Co..LinuxGL QuakeWorld..Lotus DominoR5MILO HOWTOMMBase Inst HOWTOMP3 CD BurningMail User HOWTOMajordomo MajorCoo..Man PageMasquerading Simpl..Medicine HOWTOMindTerm SSH HOWTOMobile IPv6 HOWTOMock MainframeModule HOWTOModulesMotorola Surfboard..Mozilla OptimizationMulti Distro DevNCURSES Programmin..NFS HOWTONFS Root Client mi..NIS HOWTONetMeeting HOWTONetwork boot HOWTONvidia OpenGL Conf..OLSR IPv6 HOWTOOnline Troubleshoo..Oracle 9i Fedora 3..PA RISC Linux Boot..PCTel MicroModem C..PHP Nuke HOWTOPPP HOWTOPagerPalmOS HOWTOPartitionPartition Mass Sto..Partition Mass Sto..Partition RescuePine ExchangePortSlavePost Installation ..Postfix Cyrus Web ..Pre Installation C..Print2WinPrinting HOWTOProcess AccountingProgram Library HO..Proxy ARP SubnetQmail ClamAV HOWTOQmail VMailMgr Cou..Querying libiptc H..RPM HOWTOReading List HOWTORedHat CD HOWTOReliance HOWTORemote BridgingRemote Serial Cons..SCSI 2.4 HOWTOSCSI Generic HOWTOSLIP PPP EmulatorSRM HOWTOSSL Certificates H..Scanner HOWTOScientific Computi..Scripting GUI TclTkSecure CVS PserverSecure Programs HO..Security HOWTOSecurity Quickstar..Security Quickstar..Serial Laplink HOWTOSerial Programming..Slovak HOWTOSmall MemorySmart Card HOWTOSoftware Proj Mgmt..Software Release P..Sound HOWTOSpam Filtering for..Speech Recognition..SquashFS HOWTOSybase ASA HOWTOSybase ASE HOWTOSybase PHP ApacheTCP Keepalive HOWTOTamil Linux HOWTOTimePrecision HOWTOTimeSys Linux Inst..Token RingTraffic Control HO..Traffic Control tc..UPS HOWTOUnix Hardware Buye..Unix and Internet ..UpgradeUsenet News HOWTOUser Authenticatio..VB6 to TclVMS to Linux HOWTOVPN HOWTOValgrind HOWTOVideoLAN HOWTOVim HOWTOVirtual WebWebcam HOWTOWikiText HOWTOWindows Newsreader..Wireless Link sys ..Wireless Sync HOWTOXDM XtermXDMCP HOWTOXFree Local multi ..XFree86 HOWTOXFree86 R200XFree86 Second MouseXFree86 Video Timi..XML RPC HOWTOXWindow Overview H..XWindow User HOWTOXinerama HOWTOXterminalsHtml singleI810 HOWTOLibdc1394 HOWTOOpenMosix HOWTOPhhttpd HOWTOPpp sshText

3. Device Setup

This section describes device-specific configuration operations, and general diagnostic procedures at the ATM or SONET level. Please see the adapter documentation for details on hardware installation and diagnosis. [Issues with FTP]

3.1. ATM Over TCP Setup

If you have no real ATM hardware, you can still exercise the API by using the ATM over TCP ``driver''. It emulates ATM devices which are directly wired to remote devices (i.e. there is no VPI/VCI swapping).

To establish one (bidirectional) ``wire'', become root on both systems (or run both sides on the same system to create two connected ``interfaces'') and run the following command on one of them (let's call it ``a''):

# atmtcp virtual listen

Then, on the other system (``b''), run

# atmtcp virtual connect address_of_a

Both atmtcps will report on their progress and the kernel should display messages like:

Link 0: virtual interface 2
Link 1: incoming ATMTCP connection from 127.0.0.1

and

Link 0: virtual interface 3
Link 1: ATMTCP connection to localhost

on the two systems. Note that atmtcp keeps running and that interrupting it breaks the virtual wire.

Multiple ``wires'' can be attached to the same machine by specifying a port number (default is 2812). Note that no AAL processing is performed. It is therefore not possible to receive data using a different AAL (e.g. AAL0) than the one with which the data was sent.

3.2. ZN1221/ZN1225 Tuning

The ZeitNet ZN1221 and ZN1225 adapters use pre-allocated pools of free memory buffers for receiving. Whenever a VC with a certain maximum SDU size is opened for receiving, the corresponding pool is filled with free buffers by the device driver. The adapter removes buffers while it receives data. When the number of remaining buffers falls below a certain threshold, the device driver replenishes the pool again.

The lower and the upper limits for the number of free buffers, and the threshold for adapting to a new data offset (see below for details), can be set using the zntune program. Usage:

zntune [-l low_water] [-h high_water] [-t threshold] itf [pool]

The changes are applied to all pools if no pool number is specified. Pool 2 stores 64 bytes packets, pool 3 stores 128 bytes packets, etc. Pools 0 and 1 are currently unused.

The current settings and some usage statistics can be obtained by invoking .:: hub.vroid.com ::. zntune without specifying new parameters:

zntune [-z] itf [pool]

The ``Size'' column shows the buffer size in Bytes. The ``Ref'' column shows the number of open VCs using that pool. The ``Alarm'' column shows how many times the number of free buffers has fallen below the low-water mark since the counters were reset. Similarly, the ``Under'' column shows how many times an incoming PDU had to be discarded because the corresponding pool was empty.

The columns ``Offs'', ``NxOf'', ``Count'' and ``Thres'' show the alignment adaption status. ``Offs'' is the offset of user data the driver currently expects in incoming PDUs. For single-copy, receive buffers are aligned accordingly so that data is received at page boundaries. ``NxOf'' is the user data offset of the most recently received PDU, where the offset differs from the currently assumed offset. ``Count'' is the number of PDUs that have been received in sequence with an offset of ``NxOf''. Finally, ``Thres'' is the threshold value ``Count'' has to reach for ``NxOf'' to become the new current offset.

Use the -z option to reset the ``Alarm'' and ``Under'' counters. .:: chromewebstore.google.com ::.

3.3. Files in /proc/net/atm/

Some status information about the ATM subsystem can be obtained through files in .:: drill.lovesick.jp ::. /proc/net/atm/. The file /proc/net/atm/arp contains information specific to Classical IP over ATM, see section [Issues with YAML] .:: bcraweb.bcra.gob.ar ::. CLIP.

All active ATM devices are listed in /proc/net/atm/devices. For each device, the interface number, the type label, the end system identifier (ESI), and statistics are shown. The statistics correspond to the ones available via atmdiag.

Individual ATM devices may register entries of the form .:: telegra.ph ::. type:number (e.g. eni:0) which contain device-specific information.

The files /proc/net/atm/pvc and /proc/net/atm/svc list all PVC and SVC sockets. For both types of sockets, the interface, VPI and VCI numbers are shown. For PVCs, this is followed by the AAL and the traffic class and the selected PCR for the receive and the transmit direction. For SVCs, the SVC state and the address of the remote party are shown. SVCs with the interface number 999 are used for special control purposes as indicated in the ``State'' column.

Furthermore, /proc/net/atm/vc shows buffer sizes and additional internal information for all ATM sockets.

3.4. ATM Diagnostics

Various counters of the ATM device drivers can be queried with the atmdiag program. See the corresponding man page for details.

3.5. SONET Diagnostics

The SONET diagnostics tool can be used to monitor link performance and to simulate errors. In order to get current SONET statistics, run it with the ATM interface number as the argument, e.g.

% sonetdiag 0

The counters can be reset with the -z option:

# sonetdiag -z 0

The following network failures can be simulated:[1]

sbip

insert section errors (B1)

lbip

insert line errors (B2)

pbip

insert path errors (B3)

frame

force (RX) frame loss

los

insert loss of signal

lais

insert line alarm indication signal

pais

insert path alarm indication signal

hcs

insert header checksum errors

A failure is enabled by adding the corresponding keyword on the command line. The failure is cleared by prefixing the keyword with a minus sign, e.g.

a# sonetdiag -z 0 >/dev/null
b# sonetdiag -z 0 >/dev/null
a# sonetdiag 0 los
a# sonetdiag 0 -los
b# sonetdiag 0 | grep BIP
Section BIP errors:      56200
Line BIP errors:           342
Path BIP errors:           152
a# sonetdiag 0 | grep FEBE
Line FEBE:                 342
Path FEBE:                 152

If any diagnostic error insertions are active, their keywords are shown when sonetdiag is used to obtain statistics. Note that some error insertions may be automatically switched off by the hardware.